Addressable Single Output/ Input Module

621 analogue addressable single input/output modules provide the interface to connect an electrically isolated dry-contact switched input to Numens 2-wire addressable fire detection control and indicating equipment. Up to 125 modules can be connected to each alarm zone loop.

A parallel resistive input filter allows multiple states to be monitored at the input. The states are converted to the loop communications protocol by the module, to enable them to be displayed on the control and indicating equipment.

Part No. 621-002

Category EN54 Detectors | Bases | Modules
  • Single voltage-free relay output.
  • Single input for connection to dry contact inputs.
  • Output relay for 621-002 can be powered internally, or externally to conserve loop power load (selectable at installation)
  • Monitors and signals three distinct input states
  • Normal.
  • Alarm.
  • Open-circuit.
  • Polling indicator shows quiescent operation.
  • Separate indicators for Quiescent, Alarm and Fault conditions
  • Integral isolator model available
  • DC 24 V operation.
  • Easy installation with simple address setting DIP switches.
  • Convenient 2-wire connection.
  • Available with 125 usable address settings per loop when connected to Numens control and indicating equipment.

Addressable Single Output/ Input Module

Addressable Single Output/ Input Module
  • Single voltage-free relay output.
  • Single input for connection to dry contact inputs.
  • Output relay for 621-002 can be powered internally, or externally to conserve loop power load (selectable at installation)
  • Monitors and signals three distinct input states
  • Normal.
  • Alarm.
  • Open-circuit.
  • Polling indicator shows quiescent operation.
  • Separate indicators for Quiescent, Alarm and Fault conditions
  • Integral isolator model available
  • DC 24 V operation.
  • Easy installation with simple address setting DIP switches.
  • Convenient 2-wire connection.
  • Available with 125 usable address settings per loop when connected to Numens control and indicating equipment.
Part No. 621-002
Category EN54 Detectors | Bases | Modules

Description

  • Single voltage-free relay output.
  • Single input for connection to dry contact inputs.
  • Output relay for 621-002 can be powered internally, or externally to conserve loop power load (selectable at installation)
  • Monitors and signals three distinct input states
  • Normal.
  • Alarm.
  • Open-circuit.
  • Polling indicator shows quiescent operation.
  • Separate indicators for Quiescent, Alarm and Fault conditions
  • Integral isolator model available
  • DC 24 V operation.
  • Easy installation with simple address setting DIP switches.
  • Convenient 2-wire connection.
  • Available with 125 usable address settings per loop when connected to Numens control and indicating equipment.