Kentec Syncro AS 2 Loop Apollo Protocol

Manufactured by Kentec, this Kentec Syncro As Analogue Addressable Fire Control Panel 2 Loop Apollo Protocol A80162M2 is a Syncro AS is the latest powerful and versatile single or two loop Analogue Addressable Fire Control Panel from Kentec. The AS Syncro can be field upgraded to two loops with an additional loop card.

Syncro multi-loop fire panel users will immediately be familiar with the features and functionality of the Syncro AS panel. It has the same display, help screens, menus, configuration options and controls as the Syncro panel range with all of the power and flexibility that comes from compatibility with other components of the multi-loop Syncro system and peripherals.

Syncro AS fully supports all devices from the leading, open protocol detector manufactures and can be supplied with Apollo (S90/XP95/Discovery) Argus Spectrum (Vega) or Hochiki (ESP) loop drivers, all capable of providing up to 400 milliamps of loop current for the most demanding applications.

An integral 3 Amp power supply and temperature compensated battery charger provides ample power for the two, 1 Amp rated sounder outputs, loop powered sounders and other devices.

Part No. A80162M2

Category EN54 Approved Analog Addressable Panels
  • Two addressable loops up to 126 detector each
  • Access level 2 WITH C/W enable keyswitch
  • Networkable (requires K555 network card)
  • 400 milliamp output
  • 2 programmable sounder circuits
  • 5 programmable inputs
  • 3 programmable relays
  • 24V-3A power supply
  • Stores 500 last events in event log
  • 1.2mm mild sheet steel Construction 
  • IP30 IP Rating 
  • Eight lines of 40 characters graphic LCD display
  • 9Ah 12V Maximum battery size 
  • Configuration Via Loop Explorer PC utility
  • Approved and certified to EN54-2/ EN54-4

Kentec Syncro AS 2 Loop Apollo Protocol

Kentec Syncro AS  2 Loop Apollo Protocol
  • Two addressable loops up to 126 detector each
  • Access level 2 WITH C/W enable keyswitch
  • Networkable (requires K555 network card)
  • 400 milliamp output
  • 2 programmable sounder circuits
  • 5 programmable inputs
  • 3 programmable relays
  • 24V-3A power supply
  • Stores 500 last events in event log
  • 1.2mm mild sheet steel Construction 
  • IP30 IP Rating 
  • Eight lines of 40 characters graphic LCD display
  • 9Ah 12V Maximum battery size 
  • Configuration Via Loop Explorer PC utility
  • Approved and certified to EN54-2/ EN54-4
Part No. A80162M2
Category EN54 Approved Analog Addressable Panels

Description

  • Two addressable loops up to 126 detector each
  • Access level 2 WITH C/W enable keyswitch
  • Networkable (requires K555 network card)
  • 400 milliamp output
  • 2 programmable sounder circuits
  • 5 programmable inputs
  • 3 programmable relays
  • 24V-3A power supply
  • Stores 500 last events in event log
  • 1.2mm mild sheet steel Construction 
  • IP30 IP Rating 
  • Eight lines of 40 characters graphic LCD display
  • 9Ah 12V Maximum battery size 
  • Configuration Via Loop Explorer PC utility
  • Approved and certified to EN54-2/ EN54-4
back