Manual Call Point

660 manual call points connect to addressable fire detection control and indicating equipment. Up to 125 devices can be connected to each alarm zone loop using the addressable loop communications protocol.

A pressure-activated displacement element provides a safe and convenient way for building occupants to manually initiate a fire alarm condition.

All models have an integral alarm indicator that illuminates when the manual call point has been activated. The indicator can also be configured to flash when polled by the fire detection control and indicating equipment.

In the event of a short-circuit fault in the loop transmission path, an optional integral isolator ensures the normal operation of down-stream connected devices. A yellow LED indicates when the isolator is active.

Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the operating face to the quiescent position.

The 660 manual call point range provides fire detection and alarm system designers with a Standards-compliant, premium product for life safety and property protection applications.

Part No. 660-001

Category EN54 Detectors | Bases | Modules
  • Pressure activated displacement element provides a safe user experience.
  • Integral indicator to show polling and alarm activation.
  • Resettable with simple key operation.
  • Suitable for indoor use.
  • DC 24 V operation.
  • Compatible with 2-wire fire detection and alarm systems.
  • Monitors for quiescent, alarm and fault conditions.
  • Integral loop isolator with LED activation indicator available on some models.

Manual Call Point

Manual Call Point
  • Pressure activated displacement element provides a safe user experience.
  • Integral indicator to show polling and alarm activation.
  • Resettable with simple key operation.
  • Suitable for indoor use.
  • DC 24 V operation.
  • Compatible with 2-wire fire detection and alarm systems.
  • Monitors for quiescent, alarm and fault conditions.
  • Integral loop isolator with LED activation indicator available on some models.
Part No. 660-001
Category EN54 Detectors | Bases | Modules

Description

  • Pressure activated displacement element provides a safe user experience.
  • Integral indicator to show polling and alarm activation.
  • Resettable with simple key operation.
  • Suitable for indoor use.
  • DC 24 V operation.
  • Compatible with 2-wire fire detection and alarm systems.
  • Monitors for quiescent, alarm and fault conditions.
  • Integral loop isolator with LED activation indicator available on some models.