Ramallah & Al-Bireh Governorate HQ
Address: 25 Abu Obaydah Street, Al-Bireh, Palestine
Fax: +972 2 2964680
Email: info@delta.ps


You have a comment?
leave your message below
or email us at info@delta.ps
Please enter your name
Please enter your email
Please enter a valid email address
Please enter your phone number
Please enter your message
Error
Opening Hour
Ramallah & Al-Bireh Governorate HQ
Sat - Wed 8:30 - 16:30, Thur 8:30 - 15:30
Phone
Ramallah & Al-Bireh Governorate HQ
+972 2 2964466
Ramallah & Al-Bireh Governorate HQ , Support: +972 2 2964466

Reflective Beam Line-type Smoke Detector

The 407 non-addressable reflective beam line-type smoke detector is suitable for connection to 2-wire non-addressable fire detection control and indicating equipment, or to addressable fire detection control and indicating equipment that can accept non-addressable type detectors.

The transceiver component has four selectable detection ranges, providing smoke detection over distances from 8 m to 100 m. Three sensitivity settings can be used to compensate for differences in installed environments.

Automatic compensation adjusts for lens contamination, alignment drift, ambient light conditions and transmitted beam ageing. Operational parameters are set using a separate hand-held device manager.

The 407 non-addressable reflective beam line-type smoke detectors provide fire detection and alarm system designers with a Standards-compliant, economical smoke detector for high spaces and areas with complex ceilings where point-type smoke detectors may not be suitable due to environmental conditions.

Part No. 407-001

Category Detectors | Sounders | Accessories
  • Four selectable ranges provide smoke detection for distances from 8 m to 100 m at up to 14.5 m width
  • Three selectable sensitivity settings
  • Single transceiver and separate reflector components
  • Quiescent condition indicator
  • Automatic compensation for lens contamination, alignment drift, ambient light conditions and transmitted beam ageing
  • Self-diagnostics function monitors internal faults
  • Separate Alarm and Fault relay outputs
  • Easy to install and commission using device manager.

Reflective Beam Line-type Smoke Detector

Reflective Beam Line-type Smoke Detector
  • Four selectable ranges provide smoke detection for distances from 8 m to 100 m at up to 14.5 m width
  • Three selectable sensitivity settings
  • Single transceiver and separate reflector components
  • Quiescent condition indicator
  • Automatic compensation for lens contamination, alignment drift, ambient light conditions and transmitted beam ageing
  • Self-diagnostics function monitors internal faults
  • Separate Alarm and Fault relay outputs
  • Easy to install and commission using device manager.
Part No. 407-001
Category Detectors | Sounders | Accessories

Description

  • Four selectable ranges provide smoke detection for distances from 8 m to 100 m at up to 14.5 m width
  • Three selectable sensitivity settings
  • Single transceiver and separate reflector components
  • Quiescent condition indicator
  • Automatic compensation for lens contamination, alignment drift, ambient light conditions and transmitted beam ageing
  • Self-diagnostics function monitors internal faults
  • Separate Alarm and Fault relay outputs
  • Easy to install and commission using device manager.
back